Skip to main content
Tobacco Science & Technology, 2010, 12, p. 46-48., ISSN.1002-0861

Simultaneous determination of eight heavy metals in cut filler by DRC-ICP-MS

WANG HAI-LI(1,2); TANG JIAN-GUO(2); MENG ZHAO-YU(2); ZHU WEN-HUI(1,2); LU SHE-MING(2); DAI YUN(1)
1. School of Chemistry and Biotechnology, Yunnan University of Nationalities, Kunming 650031, P.R. China; 2. Technology Center of Hongta Tobacco (Group) Co., Ltd., Yuxi 653100, Yunnan, P.R. China

To quickly and accurately determine the heavy metals in cut filler, a DRC-ICP-MS method for determining Cr, Ni, As, Se, Cd, Cs, Hg and Pb in cut filler is established with microwave digestion. The results showed that the recoveries of these elements ranged from 85.06% to 119.54% with the relative standard deviations below 10% and the limits of detection of 0.24 to 70.05 ng/L.